Can I add extra solar panels to my system?
The limiting factor on how much solar you can connect to a
Sargent PSU (Power Supply Unit) is dependant on the fuse that is protecting the
solar circuit. This is different depending on which system you have.
Below is a list of PSU series and the maximum recommended solar wattage
to be connected to the PSU.
EC325 – 120w
EC328 – 120w
EC400 – 80w
EC500 – 120w
EC600 – 120w
EC700 – 150w
EC800 – 150w
EC400+ - 150w
You can add more solar if you connect the extra panels directly
onto the leisure battery via a regulator and an appropriately sized fuse to protect
the circuit. The down side to connecting directly onto the Leisure battery with
your extra solar and not connecting it through the PSU is, you will not get a solar
reading on the control panel for the additional solar input.
Other systems in our range don’t have a solar input on the PSU’s
so these would all need to be connected directly onto the leisure battery via a
regulator and an appropriately sized fuse to protect the circuit.
There is no limit to the amount of solar wattage you can install, if you are
connecting the solar directly on to the leisure battery.
Related Articles
My system shuts down by its self randomly
One cause of the system shutting its self-down is over voltage. If your Sargent system detects a voltage higher then 15V the system will shut down. Common cause A common cause for over voltage is a faulty solar regulator but you could also have a ...
Can I charge the vehicle battery from my system?
Introduction Our electronic PSU systems fall into 2 categories with regards to vehicle battery charging: Systems not based on CAN-bus (PSU2007 with EC200, EC225 with EC100, EC325, EC328, EC155 with EC50/51, EC176 with EC361/2/3) all have manual ...
How to calibrate the EC700 and EC800 control panels
EC700 To calibrate the EC700 control panel you need to start by turning OFF the EC700 power supply unit (PSU). You then need to turn the shutdown button back on and at the same time continue to tap on the control panel screen. When the system turns ...
The battery current reading seems incorrect on my EC325 / EC328 / EC300 control panel.
If the battery current reading seems incorrect on any of the listed control panels, you may need to calibrate the current sensor in the PSU to the control panel in order to get a true reading. All of the above panels share the same layout and menu, ...
My EC155 control panel keeps beeping and the LED flashes
On the new version of the control panel (with BLUE LED’s) if you experiencing beeping and flashing of the top green LED on the Level display this would indicate that the system is detecting an overvoltage of more than 15V. On older versions of the ...